3... INTERFACE MODULES
USING THE OMP-MODL 3-37
Digital Output Signal Connections:
To utilize an MLIM-2 Output channel, connect the load positive lead to an
Output terminal (Chan E, F, G, or H) and the load negative lead to one of
the four Common terminals on the module terminal strip (Figure 3... -25).
Note that all of the four Common terminals are interconnected and connect
directly to the OMP-MODL circuit ground. Refer to Chapter 7 for steps to
generate a Terminal Strip Wiring printout for use in making field wiring
connections.
Terminal Strip
Channel E
Channel F
Common
Channel G
Channel H
LOAD
LOAD
ML124
1 2 3 4 5 6
Figure 3... -25: MLIM-2 Digital output terminal strip connections