11.. . APPENDIX A: MASTER ICON REFERENCE
USING THE OMP-MODL 11-53
MINIMUM FUNCTION ICON
FUNCTION:
Detects the minimum data value passing through the icon. The Minimum icon will
accumulate a User specified number of input samples, then calculate and output the
minimum value received.
For example, if a User wants to take temperature readings every 5 minutes and calculate
and store hourly minimums, a Program Net as shown could be used. The Thermocouple
icon is set to sample every 5 minutes per its attached Sample Rate Clock and the
Minimum icon is configured to analyze 12 readings (ie 12 readings x 5 minutes = 1 hour)
then output the minimum.
INPUTS:
Data/Logic Signal: Data type.
Update Clock: None
Enable: Processing of icon is allowed when Enable pin is unconnected or
when connected and Enable signal is TRUE.
OUTPUTS:
Output Signal: Data type. The Minimum icon updates its output with the
minimum value after receiving and analyzing the User specified number of
readings.