Appendix F ASCII / TELNET COMMANDS TABLE
Command Device / Group ID Description (see notes below if *) Example
ERCR Device ID: 000 – 031 Get continuous readings from an Get reading for sensor 7,
End Device (only -TC & -VI) ERCR007
ERDB Device ID: 000 – 031 Get sensor readings of an End Device Get reading for sensor 15,
ERDB015
ERDR Device ID: 000 – 031 Get individual reading or parameter Get the first temp. reading
Reading/parameter: a-s *4 for sensor 1, ERDR001c
ERDG Group ID: 00A - 00D, ALL Get sensor readings of a group / Get readings for all
*5 groups of sensors group B, ERDG00B
EQNF Device ID: 000 – 031 Get name, *3 status and firmware Get name for sensor 15,
version of an End Device EQNF015
EQNG Group ID00A - 00D, ALL Get name, *3 status and firmware Get name for all sensors,
version of a group/all groups of sensors EQNGALL
EQPE Device ID: 000 – 031 Get sleep period, battery voltage, signal Get sleep period for
strength, success, network address and sensor 15, EQPE015
parent address of an End Device
EQPG Group ID: 00A - 00D Get sleep period, battery voltage, signal Get sleep period of
strength, success, network address and group B, EQPG00B
parent address of a group / all groups
of sensors
ESPD Device ID: 000-031, ALL Set the sleep period for an End Device / Set sensor 15’s sleep
all sensors *1 period to 30 seconds,
ESPD015 30
ESNM Device ID: 000 – 031 Set the name of an End Device *2 Set the name of sensor 15,
ESNM015 z15
ERST Device ID: 000 – 031, ALL Reset an End Device / all sensors Reset all sensors,
ERSTALL
ESTR Device ID: 000 – 031, ALL Request End Device(s) to go into Put all sensors into
identify mode identify mode, ESTRALL
ESTP Device ID: 000 – 031, ALL Request End Device(s) to resume Resume all sensor to
normal operation normal operation, ESTPALL
CRST Reset wireless network Reset network, CRST
CSTS Get personal network ID and channel Get wireless network
information information, CSTS
FACTORY Sets the Coordinators Ethernet FACTORY xxxxxxxx
AdminPassword configurations to Factory Defaults xxxxxxxx is the Admin
Password
*1 Argument: 1 – 32767 (1 seconds to about 9 hours)
*2 Argument: xxxxxxxx (8 characters)
*3 and *4 See the following page
*5 Refer to Section 4.5.1 HTTPget using Port 2000